miio.integrations.cgllc.airmonitor.airqualitymonitor_miot module
- class miio.integrations.cgllc.airmonitor.airqualitymonitor_miot.AirQualityMonitorCGDN1(ip: str | None = None, token: str | None = None, start_id: int = 0, debug: int = 0, lazy_discover: bool = True, timeout: int | None = None, *, model: str | None = None, mapping: Dict[str, Dict[str, Any]] | None = None)[source]
Bases:
MiotDevice
Qingping Air Monitor Lite.
- actions() DescriptorCollection[ActionDescriptor]
Return device actions.
- call_action_by(siid, aiid, params=None)
Call an action.
- configure_wifi(ssid, password, uid=0, extra_params=None)
Configure the wifi settings.
- descriptors() DescriptorCollection[Descriptor]
Return a collection containing all descriptors for the device.
- classmethod get_device_group()
- get_properties(properties, *, property_getter='get_prop', max_properties=None)
Request properties in slices based on given max_properties.
This is necessary as some devices have limitation on how many properties can be queried at once.
If max_properties is None, all properties are requested at once.
- info(*, skip_cache=False) DeviceInfo
Get (and cache) miIO protocol information from the device.
This includes information about connected wlan network, and hardware and software versions.
- Parameters:
bool (skip_cache) – Skip the cache
- raw_command(command, parameters)
Send a raw command to the device. This is mostly useful when trying out commands which are not implemented by a given device instance.
- send(command: str, parameters: Any | None = None, retry_count: int | None = None, *, extra_parameters=None) Any
Send a command to the device.
Basic format of the request: {“id”: 1234, “method”: command, “parameters”: parameters}
extra_parameters allows passing elements to the top-level of the request. This is necessary for some devices, such as gateway devices, which expect the sub-device identifier to be on the top-level.
- send_handshake()
Send initial handshake to the device.
- sensors() DescriptorCollection[PropertyDescriptor]
Return read-only properties.
- set_display_temperature_unit(unit: DisplayTemperatureUnitCGDN1)[source]
Set display temperature unit.
- set_property_by(siid: int, piid: int, value: int | float | str | bool, *, value_type: Any | None = None, name: str | None = None)
Set a single property (siid/piid) to given value.
value_type can be given to convert the value to wanted type, allowed types are: int, float, bool, str
- settings() DescriptorCollection[PropertyDescriptor]
Return settable properties.
- status() AirQualityMonitorCGDN1Status [source]
Retrieve properties.
- supports_miot() bool
Return True if the device supports miot commands.
This requests a single property (siid=1, piid=1) and returns True on success.
- update_state()
Return current update state.
- retry_count = 3
- supported_models = ['cgllc.airm.cgdn1']
- timeout = 5
- class miio.integrations.cgllc.airmonitor.airqualitymonitor_miot.AirQualityMonitorCGDN1Status(data)[source]
Bases:
DeviceStatus
Container of air quality monitor CGDN1 status.
- Example::
{ ‘humidity’: 34, ‘pm25’: 18, ‘pm10’: 21, ‘temperature’: 22.8, ‘co2’: 468, ‘battery’: 37, ‘charging_state’: 0, ‘voltage’: 3564, ‘start_time’: 0, ‘end_time’: 0, ‘monitoring_frequency’: 1, ‘screen_off’: 300, ‘device_off’: 60, ‘temperature_unit’: ‘c’ }
- descriptors() DescriptorCollection[PropertyDescriptor]
Return the dict of sensors exposed by the status container.
Use @sensor and @setting decorators to define properties.
- embed(name: str, other: DeviceStatus)
Embed another status container to current one.
This makes it easy to provide a single status response for cases where responses from multiple I/O calls is wanted to provide a simple interface for downstreams.
Internally, this will prepend the name of the other class to the attribute names, and override the __getattribute__ to lookup attributes in the embedded containers.
- property charging_state: ChargingState
Return charging state.
- property display_temperature_unit
Return display temperature unit.
- class miio.integrations.cgllc.airmonitor.airqualitymonitor_miot.ChargingState(value)[source]
Bases:
Enum
An enumeration.
- Charging = 1
- NotChargable = 3
- NotCharging = 2
- Unplugged = 0
- class miio.integrations.cgllc.airmonitor.airqualitymonitor_miot.DeviceOffCGDN1(value)[source]
Bases:
Enum
An enumeration.
- After15Minutes = 15
- After1Hour = 60
- After30Minutes = 30
- Never = 0
- class miio.integrations.cgllc.airmonitor.airqualitymonitor_miot.DisplayTemperatureUnitCGDN1(value)[source]
Bases:
Enum
An enumeration.
- Celcius = 'c'
- Fahrenheit = 'f'